Eizo FLEXSCAN MX190 Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 99
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
RadiCS
Chapter 4 Acceptance Test / Constancy Test
32
English
How to Edit the Description
Enter the descriptive text of up to 128 one-byte characters in “Description”.
How to Edit a Check Point
Enter 450 characters or less into the checkpoint.
Note
Users must answer “YES” if there is no problem and must answer NO” if there is a
problem. Please consider the following things when making questions.
-
Questions must be in question formation.
e.g. “Is the Convergence setting OK?”
-
Make questions to turn answers to be “YES” if the result of the pattern check has
no problem.
How to Display a Pattern for User Setting
1)
Select [User...] from “Pattern Selection” pulldown menu and open “User Setting”
window.
2)
Click [Add Pattern], select an optional test pattern file and click [Open]. A pattern
will be added to the pattern list.
3)
Select a pattern to add to the pattern list and click [OK] to return to “Pattern”.
4) Enter a question in the pattern check if necessary.
3. Open [Luminance] and set up the test standard of luminance.
Enable the left check boxes when judging.
Screen
L’max/L’min Enter the contrast ratio. (Setting range: 0 - 999).
L’max (cd/m
2
) Enter the maximum value of the luminance. (Setting range:
0.00-999.00).
Delta L’max (%) Enter the ratio (%) of the most allowable difference comparing
Lmax with the baseline value. (Setting range: 0 - 100).
And then enter the baseline value between 0.00 to 999.00.
Delta L’min (%) Enter the ratio (%) of the most allowable difference comparing
Lmin with the baseline value. (Setting range: 0 - 100).
And then enter the baseline value between 0.00 to 99.00.
Delta (L’max/L’min)
(%)
Enter the maximum allowable difference between L’max/L’min
and the baseline value in percent (Setting range: 0 - 100).
Also enter the baseline value ranging from 0.00 to 999.00.
L’min (cd/m
2
) Enter the minimum value of the luminance. (Setting range:
0.00-99.00).
Tips
The baseline value is changed automatically when the Lmax and Lmin values are
modified in [Calibration Settings].
Vista de página 31