Chapter 3 Monitor Calibration
20
English
4. Click the right mouse button on the monitor and select “Calibration setting”.
5. Set up each item.
Tips
• Click [Default] to set the default values.
Note
• When calibrating an EIZO FlexScan M series monitor or a monitor made by another
manufacturer using a LS-100 sensor, disable the “Lamb” check box.
Measurement Level
Low Shorten the measuring time.
Standard Set up the default.
High Emphasize the measurement accuracy. It takes longer.
Target
Lmax Enter a maximum target of luminance.
Lmin Enter a minimum target of luminance.
Enable the check box, “Set as the low limit” when setting up
measured monitor minimum luminance in Lmin.
Color Select a target for color temperature target from the pulldown
menu on color monitors.
When selecting “Custom”, the color (x, y) measured on the
monocrome monitor can be set.
Select “OFF” to set up the original color of the LCD panel. The
color temperature cannot be set up in a monochrome monitor.
Tips
• The setting ranges of Lmax and Lmin vary depending on monitors. The baseline value
for a luminance check is changed automatically when the Lmax and Lmin values are
modified.